In Genie version 2.1 only one routing slip prints if you check in two issues of a serial at one time. To fix this:
  • In the folder Program Files\Inmagic\Genie\ConfigFiles, open MyReports.config.
  • Search for the entry SerDateToRoute in the Serials Reports under the Route 1on8.5x11 section. <field name="SerDateToRoute" header="Date of Issue: ">
  • Add the attribute OneEntryPerRecord= "true" This line should now read: <Field Name="SerDateToRoute" Header="Date of Issue: " OneEntryPerRecord="true" /> Save the changes.
  • Then open Mylabels.config in the same folder. Search for the entry SerDateToRoute: <Field Name="SerDateToRoute" Header="Date of Issue: " Style="font-size:12pt" UseFunction="FirstEntry"/>
  • Remove UseFunction="FirstEntry", add OneEntryPerRecord= "true" This line should now read: <Field Name="SerDateToRoute" Header="Date of Issue: " Style="font-size:12pt" OneEntryPerRecord= "true" />